{ "@context": "https://schema.org", "@type": "BreadcrumbList", "itemListElement": [ { "@type": "ListItem", "position": 1, "name": "Homepage", "item": "https://www.wago.com/au" }, { "@type": "ListItem", "position": 2, "name": "Products", "item": "https://www.wago.com/au/products" }, { "@type": "ListItem", "position": 3, "name": "Interface Electronic", "item": "https://www.wago.com/au/interface-electronic" }, { "@type": "ListItem", "position": 4, "name": "High-Current Through Terminal Blocks: Current Transformer with a Voltage Tap", "item": "https://www.wago.com/au/interface-electronic/high-current-through-terminal-block" } ] } [{"url":"/products","name":"Products","linkClass":null,"categoryCode":null},{"url":"/interface-electronic","name":"Interface Electronic","linkClass":null,"categoryCode":null},{"url":"/interface-electronic/high-current-through-terminal-block","name":"High-Current Through Terminal Blocks: Current Transformer with a Voltage Tap","linkClass":"active","categoryCode":null}]
{ "@context": "https://schema.org", "@type": "NewsArticle", "mainEntityOfPage": { "@type": "WebPage", "@id": "/high-current-through-terminal-block" }, "headline": "High-Current Through Terminal Blocks: Current Transformer with a Voltage Tap", "image": { "@type": "ImageObject", "url": "/medias/Stromwandler-Spannungsabgriff-2000x1125.jpg?context=bWFzdGVyfGltYWdlc3wzMTkzNDl8aW1hZ2UvanBlZ3xhVzFoWjJWekwyaG1NaTlvWkdRdk9URXhNekE0TWpnMU5UUTFOQzVxY0djfGVkNTEzNmE2MTc1ZjQ2NTRjZjBhOTc3NTc0OGY4ODIwZGVkZDNlZmZiYjAxMDczZDRhNThhYzUwOTAwMWY0ZWI" }, "author": { "@type": "Organization", "name": "WAGO Kontakttechnik GmbH" }, "publisher": { "@type": "Organization", "name": "WAGO Kontakttechnik GmbH", "logo": { "@type": "ImageObject", "url": "/_ui/desktop/common/images/logo.png" } }, "datePublished": "Tue Apr 17 14:02:48 CEST 2018", "dateModified": "Fri Feb 23 10:04:44 CET 2024" }
News

Energy Measurement Directly at the Infeed: Current Transformer with a Voltage Tap

A current transformer with voltage tap (855-501/150-000) is now also available for WAGO's 285-150 High-Current Through Terminal Block, simplifying energy measurement in small spaces.

Measuring consumption values for electrical energy directly at the feed of a control cabinet has never been so easy: WAGO's 285-150 High-Current Through Terminal Block for 50 mm2 (1/0 AWG) conductor cross-sections can now be retrofitted with a new current transformer with voltage tap.

  • Current and voltage tap: just 20 mm wide

  • Accuracy class: 0.5

  • Fuse-protected voltage path protects downstream measurement devices

  • No additional terminal block assemblies required for transformer short circuit and neutral point jumper