Item no. 855-5001/400-000

Split-core current transformer; 400 A / 1 A; 5 m long

Split-core current transformer; 400 A / 1 A; 5 m long
Please wait ...
PU (SPU): 1 Piece
Split-core current transformer; 400 A / 1 A; 5 m long
Please wait ...
PU (SPU): 1 Piece
Details
Description
Downloads
Approvals
Related products
Technical data
Safety and protection
Connection data
Physical data
Mechanical data
Material data
Environmental requirements
Standards and specifications
Commercial data
Product classification
Environmental Product Compliance
Other customers also purchased
: 2002-1671
Disconnect terminal block; knife disconnect; rail mount; 2-conductor; 5.2 mm wide; gray
: 2002-1691
TOPJOB®S end/intermediate plate; for 2002-16xx series terminal blocks; 1.0 mm wide; gray
: 2002-3231
TOPJOB®S triple-deck terminal block; through/through/through (L/L/L); with marker carrier; rail mount; 2-conductor; 5.2 mm wide; gray
: 2007-8821
2-conductor disconnect/test terminal block; e.g., current transformer circuits; with receptacle for adjacent jumper with switch lever; for 4 mm Ø test plugs; for DIN-rail 35 x 15 and 35 x 7.5; 6 mm²; Push-in CAGE CLAMP®; 6,00 mm²; gray
: 282-882
Locking cover; mechanically locks multiple links; 2-pole; transparent
: 709-581
Switchgear cabinet outlet; for DIN-rail and screw mounting; for plug, type F, CEE 7/4 (Schuko); common in DE, NL, AT; with LED status indicator; with Push-in Cage Clamp double connection; light gray
: 750-517
2-channel relay output; AC 250 V; 1 A; Potential-free; 2 changeover contacts
: 855-4001/200-001
Split-core current transformer; 200 A / 1 A; 3 m long
: 855-5001/500-000
Split-core current transformer; Primary rated current: 500 A; Secondary rated current: 1 A; Rated power: 0.5 VA; Accuracy class: 1
: 855-5005/600-000
Split-core current transformer; 600 A / 5 A; 3 m long
: 855-501/150-000
Current and voltage tap up to 50 mm²; Primary rated current: 150 A; Secondary rated current: 1 A; Rated power: 0.2 VA; Accuracy class: 0.5; fused
: 855-951/250-000
Plug-in current transformer; 250 A / 1 A; for POWER CAGE CLAMP®; voltage tap, fuse-protected
: 857-152
Basic relay; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 6 A; Module width: 5 mm; Module height: 15 mm
: 879-3000
Energy meter (MID24); for direct connection; 65A; 3x230/400V; 50Hz; Modbus® and M-Bus; 2 x S0 interface; 4PU
: 879-3020
Energy meter (MID); for direct connection; 65A; 3x230/400V; 50Hz; Modbus® and M-Bus; 2 x S0 interface; 4PS
: 879-3040
Energy meter (MID25); for transformer connection; 1 A / 5 A; 3x230/400V; 50Hz; Modbus® and M-Bus; 2 x S0 interface; 2PU CT