Shape
Item no. 750-333/040-000
Fieldbus Coupler PROFIBUS DP; 2nd Generation; 12 MBd; Extreme
Item no. 750-333/040-000

750 XTR Series – I/O System Fieldbus Coupler PROFIBUS DP; 2nd Generation; 12 MBd; Extreme

Item no. 750-333/040-000
Fieldbus Coupler PROFIBUS DP; 2nd Generation; 12 MBd; Extreme

Description

The 750-333 Fieldbus Coupler maps the peripheral data of all the I/O modules of the WAGO-I/O-SYSTEM on PROFIBUS DP.

When initializing, the coupler determines the node's module structure and creates the process image of all inputs and outputs. In order to optimize addresses, the I/O modules with a bit width smaller than 8 are grouped in one byte.

It is furthermore possible to deactivate I/O modules and to modify the image of the node according to the connected signals without having to modify the existing application.

The diagnostic concept is based on ID- and channel-related diagnostics according to EN 50170. This does away with the need for programming modules to evaluate manufacturer-specific diagnostic data.

The module is ideally suited for operation in harsh environmental conditions:
- strongly extended temperature range
- higher dielectric strength and EMC resistance
- higher vibration and shock resistance


Note:

Notice: GSD files required

Product details

Details

Technical Data

Communication PROFIBUS
Number of fieldbus nodes on the master max. 96
Max. no. of I/O points 6000
Baud rate 9.6 kBd … 12 MBd
Fieldbus segment length max. 1200 m
Transmission medium Cu cable acc. to EN 50170
Transmission time typ. 1 ms (10 couplers; 32 digital I/Os per coupler at 12 Mbaud) max. 3.3 ms
Number of modules per node max. 63
Input and output process image (internal) max. 244 Byte/244 Byte
Max. input and output process image (fieldbus) 244 Byte/244 Byte
System supply voltage DC 24 V (−25 … +30 %); via wiring level (CAGE CLAMP® connection). Specified values for ambient temperatures under laboratory conditions +15 … +35 °C. For −40 … +55 °C: 24 V (−25 … +20 %). For +55 … +70 °C: 24 V (−25 … +10 %). Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)
Current consumption, system supply 200 mA
Total current for system supply 1800 mA
Field supply voltage DC 24 V; via power jumper contacts
Input current typ. at rated load (24 V) 500 mA
Efficiency of the power supply (typ.) at nominal load (24 V) 90 %
Rated surge voltage 1 kV
Number of outgoing power jumper contacts 2
Current carrying capacity of the power jumper contacts 10 A
Ratings per IEC/EN 60664-1
Standard EN 50170

Connection data

Connection technology: communication/fieldbus PROFIBUS: 1 x D-Sub 9 socket
Connection technology: field supply 4 x CAGE CLAMP®
Connection technology: system supply 2 x CAGE CLAMP®
Connection technology: device configuration 1 x 4-pole male connector
Number of connections: system supply 2
Connection type (1) System-/Feldversorgung
Connection technology: system supply CAGE CLAMP®
Solid conductor 0.25 … 2.5 mm² / 24 … 14 AWG
Fine-stranded conductor 0.25 … 2.5 mm² / 24 … 14 AWG
Strip length 8 … 9 mm / 0.31 … 0.35 Inch
Number of connections: device configuration 1
Connection technology: device configuration 4-pole male connector

Geometrical Data

Width 50.5 mm / 1.988 Inch
Height 71.1 mm / 2.799 Inch
Height from upper-edge of DIN-35 rail 63.9 mm / 2.516 Inch
Depth 100 mm / 3.937 Inch

Mechanical data

Type of mounting DIN-35 rail

Material Data

Housing material Polycarbonate, polyamide 6.6
Fire load 0.324 MJ
Weight 180 g
Conformity marking CE

Environmental Requirements

Ambient temperature (operation) -40 … 70 °C
Ambient temperature (storage) -40 … 85 °C
Degree of protection IP20
Degree of pollution (5) 2 per IEC 61131-2
Operating altitude without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); max.: 5000 m
Mounting position horizontal (standing/lying) or vertical
Relative air humidity (no condensation) 95 %
Relative humidity Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E DIN 40046-721-3 (except wind-driven precipitation, water and ice formation)
Vibration resistance acc. to IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155, EN 61373
Shock resistance acc. to IEC 60068-2-27 (15g/11 ms/half-sine/1000 shocks; 25g/6 ms/1000 shocks), EN 50155, EN 61373
EMC immunity to interference acc. to EN 61000-6-1, -2, EN 61131-2, marine applications, EN 50121-3-2, -4, -5, EN 60255-26, EN 60870-2-1, EN 61850-3, IEC 61000-6-5, IEEE 1613, VDEW: 1994
EMC emission of interference acc. to EN 61000-6-4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Permissible H2S contaminant concentration at a relative humidity < 75 % 10 ppm
Permissible SO2 contaminant concentration at a relative humidity < 75 % 25 ppm

Commercial data

Packaging type BOX
Country of rigin DE
GTIN 4050821460138
Customs Tariff No. 85176200000
Product Group 15 (Remote I/O)

Approvals / Certificates

Ex-Approvals

Logo
Approval
Certificate name
Logo
Approval: ATEX
TUEV Nord Cert GmbH
Certificate name: TUEV 17 ATEX 193969X
English
Logo
Approval: UL
Underwriters Laboratories Inc.
(HAZARDOUS LOCATIONS)
Certificate name: E198726 Sec.1
English

Ship Approvals

Logo
Approval
Certificate name
Logo
Approval: ABS
American Bureau of Shipping
Certificate name: 16-HG1510784-PDA
English
Logo
Approval: GL
Germanischer Lloyd
Certificate name: 95043-14HH
English
Logo
Approval: LR
Lloyds Register
Certificate name: 17/20073 LR
English

UL-Approvals

Logo
Approval
Certificate name
Logo
Approval: UL
UL International Netherlands B.V.
(ORDINARY LOCATIONS)
Certificate name: E175199 Sec.1
English

Downloads

Documentation

Manual

PROFIBUS DP/V1 12 Mbd /XTR for eXTReme environmental conditions; 12 Mbaud; digital and analog signals
Jun 13, 2016
PDF 7.1 MB
System Manual /XTR Basic conditions and recommendations for higher operational safety
Aug 11, 2016
PDF 2.9 MB

Bid Text

750-333/040-000
Jan 19, 2016
DOC 35.8 kB
German

System Description

750 XTR Series I/O-System ‒ General Product Information
Jun 6, 2017
PDF 881.2 kB

Libraries

Device Description File

GSD files for PROFIBUS / 750, 752, 755, 758 and 767 Series
6.1, Jul 25, 2017
ZIP 4.2 MB
English

Runtime Software

Firmware

Firmware: 750-333/040-000 Fieldbus Coupler PROFIBUS DP; 2nd Generation; 12 MBd; Extreme
19, May 8, 2017
zip 542.9 kB

Compatible products

Carrier rail

General accessories

Marking accessories

shield connection

wiring and connectors

Product family

750 XTR Series – I/O System

I/O-System 750 XTR: Dort automatisieren, wo jedes andere System an seine Grenzen stößt – und das zuverlässig und wirtschaftlich! XTR – dieses Kürzel im Systemnamen steht für extremen Schutz vor klimatischen Einflüssen, Schwingungen, Erschütterungen und Überspannungen.

Your Shopping Cart

Added to shopping cart.
Go to the shopping cart Request offer. Continue shopping.

Are you sure?

Add project directly

Please enter an exact item number (e.g., 2002-1201) and confirm your entry with the “Enter” key. Use the “Tab” key to navigate between the columns.
PU (SPU)
Change Country

You are leaving the currently selected country website and will be logged out. Your user account only applies to one country. Your newly selected country website has other contacts and may have different content and functions.

Down
To top of page