Shape
Item no. 750-882
Controller ETHERNET; 3rd Generation; Media Redundancy
Item no. 750-882

Controller ETHERNET; 3rd Generation; Media Redundancy

Item no. 750-882
Controller ETHERNET; 3rd Generation; Media Redundancy

Description

In conjunction with the WAGO-I/O-SYSTEM, the ETHERNET Controller serves ETHERNET networks requiring fast and safe media redundancy. The controller supports all digital, analog and specialty modules found within the 750/753 Series, and is suitable for data rates of 10/100 Mbit/s.

Media redundancy is achieved by operating the controller in two separate networks – which is accessible via two different IP addresses (including two MAC IDs). Cross communication between separate channels is not possible. The two separate ETHERNET interfaces allow redundant connection of two transmission paths (no hub or switch required). Both interfaces support Auto-Negotiation and Auto-MDI(X). The DIP switch configures the last byte of both default IP addresses and may be used for IP address assignment (DHCP, BootP).

The media redundancy controller is designed for fieldbus communication via MODBUS in ETHERNET networks. It also supports a wide variety of standard ETHERNET protocols (e.g., HTTP, BootP, DHCP, DNS, FTP). An integrated Webserver provides user configuration options, while displaying PLC status information.

The IEC 61131-3 programmable controller is multitasking-capable and features a battery-backed RTC.

Product details

Details

Technical Data

Communication EtherNet/IP
Modbus TCP
Ethernet
Ethernet protocol HTTP
BootP
DHCP
DNS
SNTP
FTP
SNMP
Redundancy function via two logically separated ETHERNET interfaces
Visualization Web-Visu
CPU 32 bits
Programming languages per IEC 61131-3 Instruction List (IL)
Ladder Diagram (LD)
Function Block Diagram (FBD), Continuous Function Chart (CFC)
Structured Text (ST)
Sequential Function Chart (SFC)
Programming environment WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)
Configuration options WAGO-I/O-CHECK
Web-based management
Baud rate (communication/fieldbus 1) 10/100 Mbit/s
Baud rate 10/100 Mbit/s
Transmission medium (communication/fieldbus) Twisted Pair S-UTP; 100 Ω; Cat. 5; Line length (max.): 100 m
Transmission performance Class D acc. to EN 50173
Program memory 1024 kByte
Data memory 512 kByte
Software non-volatile memory 32 kbyte
Number of modules per node max. 250
Number of I/O modules without bus extension max. 64
Max. input and output process image (fieldbus) 1020 Words/1020 Words
Indicators LED (LINK/ACT) green: Network connection Port 1 … 2; LED (MS, NS) red/green: Status of node, network; LED (I/O, USR) red/green/orange: Internal data bus status, status programmable by user; LED (A, B) green: System power supply status, field supply
System supply voltage DC 24 V (−25 … +30 %); via wiring level (CAGE CLAMP® connection)
Input current typ. at rated load (24 V) 500 mA
Efficiency of the power supply (typ.) at nominal load (24 V) 90 %
Current consumption, system supply 450 mA
Total current for system supply 1700 mA
Field supply voltage DC 24 V (-25 … 30 %); via power jumper contacts
Current carrying capacity of the power jumper contacts 10 A
Number of outgoing power jumper contacts 3
Isolation 500 V system/supply

Connection data

Connection technology: communication/fieldbus EtherNet/IP: 2 x RJ-45; Modbus TCP/UDP: 2 x RJ-45
Connection technology: system supply 2 x CAGE CLAMP®
Connection technology: field supply 6 x CAGE CLAMP®
Connection type (1) System-/Feldversorgung
Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Strip length 8 … 9 mm / 0.31 … 0.35 Inch
Connection technology: device configuration 1 x 4-pole male connector

Geometrical Data

Width 61.5 mm / 2.421 Inch
Height 71.9 mm / 2.831 Inch
Height from upper-edge of DIN-35 rail 64.7 mm / 2.547 Inch
Depth 100 mm / 3.937 Inch

Mechanical data

Weight 159.179 g
Color light gray
Housing material Polycarbonate, polyamide 6.6
Conformity marking CE

Environmental Requirements

Ambient temperature (operation) 0 … 55 °C
Ambient temperature (storage) -25 … 85 °C
Degree of protection IP20
Degree of pollution (5) 2 per IEC 61131-2
Operating altitude without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); max.: 5000 m
Relative air humidity (no condensation) 95 %
Mounting position any
Type of mounting DIN-35 rail
Vibration resistance 4g per IEC 60068-2-6
Shock resistance 15g per IEC 60068-2-27
EMC immunity to interference acc. to EN 61000-6-2, marine applications
EMC emission of interference acc. to EN 61000-6-3, marine applications
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Fire load 3.434 MJ
Permissible H2S contaminant concentration at a relative humidity < 75 % 10 ppm
Permissible SO2 contaminant concentration at a relative humidity < 75 % 25 ppm

Commercial data

Packaging type BOX
Country of rigin DE
GTIN 4050821174929
Customs Tariff No. 85371091990
Product Group 15 (Remote I/O)

Approvals / Certificates

Ex-Approvals

Logo
Approval
Certificate name
Logo
Approval: ATEX
TUEV Nord Cert GmbH
Certificate name: TÜV 07 ATEX 554086 X en.
Logo
Approval: TUEV Nord
TUEV Nord Cert GmbH
Certificate name: IECEx TUN 09.0001 X
English
Logo
Approval: UL
Underwriters Laboratories Inc.
(HAZARDOUS LOCATIONS)
Certificate name: E198726 Sec.1
English

Ship Approvals

Logo
Approval
Certificate name
Logo
Approval: BV
Bureau Veritas S.A.
Certificate name: 30389/A1 BV
English
Logo
Approval: DNV
DNV Germany GmbH
Certificate name: A-14093
Logo
Approval: GL
Germanischer Lloyd
Certificate name: 11 631 - 10 HH
English
Logo
Approval: KR
Korean Register of Shipping
Certificate name: HMB05880-AC001
Logo
Approval: LR
{Lloyd’s Register EMEA
Certificate name: 02/20026 (E5)
English
Logo
Approval: NK
Nippon Kaiji Kyokai
Certificate name: TA17255M
English
Logo
Approval: PRS
Polski Rejetr Statkow
Certificate name: TE/1989/880590/13
English
Logo
Approval: RINA
RINA Germany GmbH
Certificate name: ELE134212XG

UL-Approvals

Logo
Approval
Certificate name
Logo
Approval: UL
UL International Netherlands B.V.
(ORDINARY LOCATIONS)
Certificate name: E175199 Sec.1
English

Downloads

Documentation

Manual

ETHERNET media redundancy programmable fieldbus controller 10/100 Mbit/s; digital and analog signals
Aug 3, 2016
PDF 14.4 MB
WAGOupload For commissioning, management and configuration of ETHERNET 750 Series fieldbus controllers
Jun 7, 2017
V 3.0.0, Jun 1, 2017
PDF 6.0 MB
WAGO MODBUS Master Configurator for configuration of MODBUS networks in WAGO-I/O-PRO (CODESYS)
Sep 22, 2014
PDF 1.3 MB
Use in Hazardous Environments Term definition, marking and installation regulations
May 8, 2014
PDF 1.0 MB
Design Notes Basic conditions and recommendations for higher operational safety
May 3, 2011
PDF 1.5 MB

Quick-Start Guide

Programmable Fieldbus Controller ETHERNET 750-88x 10/100 Mbit/s; digital and analog signals
Nov 28, 2012
PDF 4.4 MB

Bid Text

750-882 IO, Controller
Jan 22, 2016
DOC 31.2 kB
German

System Description

750 Controller, General Product Information
Jun 6, 2017
PDF 426.1 kB
Overview on WAGO-I/O-SYSTEM 750 approvals
Jun 6, 2017
PDF 314.9 kB

Application Notes

Application Note CoDeSys 2.3

Application Note PowerMeasurement_03 Library This application note describes how current, voltage, effective power, power factor and energy consumption can be measured using 3-phase power measurement modules (750-493).
Mar 19, 2014
ZIP 954.5 kB
Application Note: DMX_02 This application note describes how a DMX master for DMX device control can be performed via 750-652 serial interface.
Apr 26, 2017
ZIP 751.0 kB
Application Note DaylightSaving This Application Note explains how automatic switching between standard/daylight savings time can be implemented on the Ethernet fieldbus controller 750-841, starting from Firmware version 11.
Mar 19, 2014
ZIP 682.4 kB
HVAC System Macros WAGO provides system macros for HVAC applications that are based on Building_HVAC_03.lib.
Jun 14, 2017
ZIP 13.4 MB
Application Note: MpBus_03 Library This Application Note explains how a WAGO fieldbus controller sets up communication to the MP-bus actuators via the MP-bus master module (750-643).
Apr 13, 2018
ZIP 1.4 MB
GRUNDFOS GENIbus interface, application note This application note describes how communication between the WAGO-I/O-SYSTEM and the Grundfos MAGNA series circulation pumps can be performed via GENIbus interface.
Mar 20, 2017
ZIP 286.6 kB
Connection of the WS-K xx T ModBus HVAC Electronic Weather Forecast Station The Application Note explains how communication between the WAGO-I/O-SYSTEM and an HKW electronic weather forecast station (compact) can be established.
V 1.1, Jul 7, 2017
ZIP 781.1 kB
Application Note Scheduler_03.lib This application note describes different applications of the Scheduler_03.lib library.
Mar 5, 2014
ZIP 1.8 MB
Connection of a Thermokon Thanos SR L MODBUS room control unit to the WAGO-I/O-SYSTEM The fundamental method of setting up communication between the WAGO I/O System and the Thanos SR L MODBUS room operating panel from Thermokon is described in this application note.
Mar 19, 2014
ZIP 313.2 kB
Application Note Connecting with an iPod Touch This Application Note explains the basic procedures for access to the WAGO Ethernet Controller 750-8xx or the WAGO Ethernet Coupler 750-3xx using an iPod Touch.
Mar 19, 2014
ZIP 440.7 kB
German
Connection of Thermokon Multi-function room control units WRF 08 The fundamental way of carrying out the communication between the WAGO I/O System and the multi-function room operating panel (WRF08 RS485 Modbus) from Thermokon is described in this application note.
Mar 19, 2014
ZIP 931.8 kB
Connection of DMX devices to the WAGO-I/O-SYSTEM via the ArtNet-DMX STAGE-PROFI 1.1 This application note describes connecting the ArtNet-DMX STAGE-PROFI 1.1 to the WAGO-I/O-SYSTEM. The ArtNet-DMX STAGE-PROFI 1.1 can be operated as a DMX master and a DMX slave.
Mar 19, 2014
ZIP 1.5 MB
Application Note for the 750-495 3-Phase Power Measurement Module The application note for the 3-Phase Power Measurement Module 750-495 shows how the measured values ​​of the power measurement module can be read. It is also shown how the power module can be configured using the WAGO-I/O-PRO- V2.3 visualization tool.
Mar 20, 2014
ZIP 1.8 MB
Application Note for the 750-494 3-Phase Power Measurement Module The application note for the 3-Phase Power Measurement Module 750-494 shows how the measured values ​​of the power measurement module can be read. It is also shown how the power module can be configured using the WAGO-I/O-PRO- V2.3 visualization tool.
Nov 11, 2014
ZIP 1.7 MB
Application Note: EnOcean_06 Library This application note describes how communication between the WAGO-I/O-SYSTEM and different EnOcean wireless sensors can be implemented using the EnOcean_06.lib library.
Nov 30, 2016
ZIP 842.0 kB
Application Note Library ModuleAccess_01 These instructions describe the use of the ModuleAccess_01.lib library using 4 examples.
Jan 29, 2016
ZIP 1.0 MB
Application Note Weather Station Elsner P03 Modbus This application note describes how communication can be set up between the WAGO I/O System and the ELSNER P03/3 weather station with a Modbus interface.
Mar 18, 2014
ZIP 275.6 kB
Connection of Thermokon Multi-function room control units WRF 06 The fundamental method of setting up communication between the WAGO I/O System and the multi-function room operating panel (WRF06 RS485 Modbus) from Thermokon is described in this application note.
Apr 8, 2016
ZIP 413.6 kB
HVAC System Macros for TRIC In this file you will find both templates and macros for the TRIC planning software. TRIC is a tool for planners and manufacturers of HVAC systems, which complies with the VOB [Construction Tendering and Contract Regulations], VDI [Association of German Engineers], and DIN EN ISO guidelines.
Jul 24, 2015
ZIP 76.8 MB
German
Application note: DALI 753-647 Configuration Interface This application note describes the WAGO DALI Configurator, the integration of the DALI visualization for configuring various sensor types and the implementation in a program.
Jun 20, 2017
ZIP 2.9 MB

Libraries

Library

ModuleAccess_01.lib The ModuleAccess_01 library provides both module configuration and access to its process data within a CoDeSys project without the use of WAGO I/O Check.
Feb 16, 2018
ZIP 1.5 MB

Device Description File

MIB file for Ethernet controller / 750 Series
2.0, Apr 3, 2012
ZIP 6.1 kB
English

Device Driver

WAGO USB Service Cable Driver / 750 and 857 Series
6.5.3.0, Sep 10, 2014
ZIP 4.8 MB
English

Engineering-Software

Configuration and Commissioning Software

WAGO BootPServer / 750 and 767 Series
1.0, May 24, 2011
ZIP 1.1 MB
English
WAGO-IO-PRO Demo Version / 750, 758 and 762 Series
2.3.9.53, Jun 20, 2017
ISO 334.5 MB
English
WAGO Extension Setting / 750 Series
2.0.2, May 24, 2011
ZIP 5.4 MB
English
WAGOupload Small Version WAGOupload is an independent PC software for transmission,
1.9.4.0, Nov 6, 2017
ZIP 3.6 MB
WAGOupload Full Version WAGOupload is an independent PC software for transmission,
1.9.4.0, Nov 6, 2017
ZIP 53.1 MB
(759-316) WAGO Ethernet Settings / 750 Series
6.8.2.2, Jan 25, 2017
EXE 16.0 MB

Runtime Software

Firmware

Firmware: 750-882 Controller ETHERNET; 3rd Generation; Media Redundancy
10, Dec 14, 2016
zip 3.6 MB

smartDATA

CAD data

3D Download 750-882
URL

Compatible products

Carrier rail

General accessories

Marking accessories

shield connection

wiring and connectors

Your Shopping Cart

Added to shopping cart.
Go to the shopping cart Request offer. Continue shopping.

Are you sure?

Add project directly

Please enter an exact item number (e.g., 2002-1201) and confirm your entry with the “Enter” key. Use the “Tab” key to navigate between the columns.
PU (SPU)
Change Country

You are leaving the currently selected country website and will be logged out. Your user account only applies to one country. Your newly selected country website has other contacts and may have different content and functions.

Down
To top of page