Shape
Item no. 750-8202/025-001
Controller PFC200; 2 x ETHERNET, RS-232/-485; Telecontrol technology; Ext. Temperature
Item no. 750-8202/025-001

Controller PFC200; 2 x ETHERNET, RS-232/-485; Telecontrol technology; Ext. Temperature

Item no. 750-8202/025-001
Controller PFC200; 2 x ETHERNET, RS-232/-485; Telecontrol technology; Ext. Temperature

Description

The PFC200 Controller is a compact PLC for the modular WAGO-I/O-SYSTEM. Besides network and fieldbus interfaces, the controller supports all digital, analog and specialty modules found within the 750/753 Series.

Two ETHERNET interfaces and an integrated switch enable line topology wiring.

An integrated Webserver provides user configuration options, while displaying PFC200 status information.

Besides the processing industry and building automation, typical applications for the PFC200 include standard machinery and equipment control (e.g., packaging, bottling and manufacturing systems, as well as textile, metal and wood processing machines).

Programming per IEC 61131-3

  • Programmable via WAGO-I/O-PRO V2.3
  • Direct connection of WAGO I/O modules
  • 2 x ETHERNET (configurable), RS-232/-485
  • Linux operating system with RT‐Preempt patch
  • Configuration via CODESYS or Web-Based Management interface
  • Maintenance-free

Product details

Details

Technical Data

Communication Modbus TCP
Ethernet
Modbus RTU
RS-232 serial interface
RS-485 interface
Telecontrol protocols
Ethernet protocol DHCP
DNS
NTP
FTP
FTPS
SNMP
HTTP
HTTPS
SSH
Telecontrol protocols IEC 60870-5-101/-103/-104
IEC 61400-25
IEC 61850-7
DNP3
Visualization Web-Visu
Operating system Real-time Linux (with RT-Preempt patch)
CPU Cortex A8, 600 MHz
Programming languages per IEC 61131-3 Instruction List (IL)
Ladder Diagram (LD)
Function Block Diagram (FBD), Continuous Function Chart (CFC)
Structured Text (ST)
Sequential Function Chart (SFC)
Programming environment WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)
Configuration options e!COCKPIT
WAGO-I/O-CHECK
Web-based management
e!RUNTIME library
CODESYS Library
Baud rate (communication/fieldbus 1) 10/100 Mbit/s
Baud rate ETHERNET: 10/100 Mbit/s
Transmission medium (communication/fieldbus) ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; Line length (max.): 100 m
Main memory (RAM) 256 MB
Internal memory (flash) 256 MB
Hardware non-volatile memory 128 kbyte
Program memory 16 MByte
Data memory 64 MByte
Software non-volatile memory 128 kbyte
Type of memory card SD and SDHC up to 32 GB (All guaranteed properties are only valid in connection with the WAGO 758-879/000-001 memory card.)
Memory card slot Push-push mechanism, sealable cover lid
Number of modules per node max. 250
Number of I/O modules without bus extension max. 64
Input and output process image (internal) max. 1000 Words/1000 Words
Input and output process image (MODBUS) max. 1000 Words/1000 Words
Indicators LED (SYS, RUN, I/O, U1 … U7) red/green/orange: Status system, program, internal data bus, status programmable by user (can be used via CODESYS library); LED (A, B) green: System power supply status, field supply
System supply voltage DC 24 V (−25 … +30 %); via wiring level (CAGE CLAMP® connection)
Input current typ. at rated load (24 V) 550 mA
Total current for system supply 1700 mA
Field supply voltage DC 24 V (-25 … 30 %); via power jumper contacts
Current carrying capacity of the power jumper contacts 10 A
Number of outgoing power jumper contacts 3
Isolation 500 V system/supply

Connection data

Connection technology: communication/fieldbus Modbus TCP/UDP: 2 x RJ-45; Modbus RTU: 1 x D-Sub 9 socket; RS-232 serial interface: 1 x D-Sub 9 socket; RS-485 interface: 1 x D-Sub 9 socket; Telecontrol protocols: 1 x D-sub 9 socket; Telecontrol protocol IEC 60870-5-104: 1 x RJ-45; Telecontrol protocol IEC 61850: 1 x RJ-45; Telecontrol protocol DNP3: 1 x RJ-45 or D-sub 9 socket
Connection technology: system supply 2 x CAGE CLAMP®
Connection technology: field supply 6 x CAGE CLAMP®
Connection type (1) System-/Feldversorgung
Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Strip length 8 … 9 mm / 0.31 … 0.35 Inch
Connection technology: device configuration 1 x 4-pole male connector

Geometrical Data

Width 78.6 mm / 3.094 Inch
Height 71.9 mm / 2.831 Inch
Height from upper-edge of DIN-35 rail 64.7 mm / 2.547 Inch
Depth 100 mm / 3.937 Inch

Mechanical data

Weight 231.307 g
Color light gray
Housing material Polycarbonate, polyamide 6.6
Conformity marking CE

Environmental Requirements

Ambient temperature (operation) -20 … 60 °C
Ambient temperature (storage) -40 … 85 °C
Degree of protection IP20
Degree of pollution (5) 2 per IEC 61131-2
Operating altitude without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); max.: 5000 m
Relative air humidity (no condensation) 95 %
Relative humidity Short-term condensation per Class 3K6/IEC EN 60721-3-3 and E DIN 40046-721-3, taking a temperature range of −20 … +60 °C into consideration (except wind-driven precipitation, water and ice formation)
Mounting position any
Type of mounting DIN-35 rail
Vibration resistance 4g per IEC 60068-2-6
Shock resistance 15g per IEC 60068-2-27
EMC immunity to interference acc. to EN 61000-6-2, marine applications
EMC emission of interference acc. to EN 61000-6-3, marine applications
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Permissible H2S contaminant concentration at a relative humidity < 75 % 10 ppm
Permissible SO2 contaminant concentration at a relative humidity < 75 % 25 ppm

Commercial data

Packaging type BOX
Country of rigin DE
GTIN 4050821892304
Customs Tariff No. 85371091990

Approvals / Certificates

Ex-Approvals

Logo
Approval
Certificate name
Logo
Approval: ATEX
TUEV Nord Cert GmbH
Certificate name: TUEV_14_ATEX_148929_X
English
Logo
Approval: ATEX
TUEV Nord Cert GmbH
Certificate name: IECEx_TUN_14.0035_X
English
Logo
Approval: UL
Underwriters Laboratories Inc.
(HAZARDOUS LOCATIONS)
Certificate name: E198726 Sec.1
English

Ship Approvals

Logo
Approval
Certificate name
Logo
Approval: DNV GL
Det Norske Veritas, Germanischer Lloyd
Certificate name: TAA00001J4
English

UL-Approvals

Logo
Approval
Certificate name
Logo
Approval: UL
UL International Netherlands B.V.
(ORDINARY LOCATIONS)
Certificate name: E175199 Sec.1
English

Downloads

Documentation

Manual

WAGO-I/O-SYSTEM 750 IEC-61850 Solution
Jan 8, 2018
PDF 19.7 MB
WAGO-I/O-SYSTEM 750 DNP3 Solution
Jan 9, 2018
PDF 4.3 MB
WAGO MODBUS Master Configurator for configuration of MODBUS networks in WAGO-I/O-PRO (CODESYS)
Sep 22, 2014
PDF 1.3 MB
PFC200 CS 2ETH RS Telecontrol/T PLC – PFC200 Controller
Apr 12, 2017
PDF 7.3 MB
WAGO-I/O-SYSTEM 750 IEC-60870 Solution
Jan 8, 2018
PDF 4.0 MB

Quick-Start Guide

WAGO-I/O-SYSTEM 750 IEC-61850 Solution
Jan 8, 2018
PDF 19.7 MB
WAGO-I/O-SYSTEM 750 DNP3 Solution
Jan 9, 2018
PDF 4.3 MB
WAGO-I/O-SYSTEM 750 IEC-60870 Solution
Jan 8, 2018
PDF 4.0 MB

Bid Text

750-8202/025-001 PFC200
Jan 22, 2016
DOC 36.4 kB
German

Tutorial

WAGO IEC 61400-25 solution (Windmill)
Dec 1, 2011
1.0, Dec 1, 2011
WMV 20.4 MB
Tutorial WAGO IEC 61850 / 61400 solution
Dec 1, 2011
1.0, Dec 1, 2011
WMV 45.4 MB
WAGO IEC 61850 solution (Transformer)
1.0, Sep 12, 2012
Dec 1, 2011
WMV 56.8 MB
Establish connection to a controller using SSH In this video we are demonstrating how to establish a SSH connec-tion with a controller using for example PuTTY to be able to work with the LINUX console. Contents: 0:21 Download and install the SSH client; 0:40 Establish the SSH connection; 0:50 Log on to the Controller
Jan 23, 2018
1.0, Jan 23, 2018
MP4 29.0 MB
Set IP address with Ethernet Settings In this video we are demonstrating how you can set a IP address with Ethernet Settings. Content: 00:27 – Chapter #1 Download and install software; 00:56 – Chapter #2 Open Ethernet Settings; 01:10 – Chapter #3 Establish serial Connection; 01:34 – Chapter #4 Set IP address; 02:10 – Chapter #5 Check IP address
Jan 23, 2018
3.0, Jan 23, 2018
MP4 88.3 MB

Additional Information

External license agreement for open source software In Wago products
Aug 26, 2016
PDF 1.5 MB

System Description

Controller PFC100/200, General Product Information
Jun 6, 2017
PDF 524.3 kB
Overview on WAGO-I/O-SYSTEM 750 approvals
Jun 6, 2017
PDF 314.9 kB

Application Notes

Application Note CoDeSys 2.3

Application note for installing a MySQL-Server on a PFC-Controller This Application Note explains how a MySQL-Server can be set up and used on a PFC 200. The Application shows how measurement values of the 3-Phase Power Measurement Module can be written into a database.
Sep 20, 2017
ZIP 4.1 MB

Engineering-Software

Configuration and Commissioning Software

WAGO-IO-PRO Demo Version / 750, 758 and 762 Series
2.3.9.53, Jun 20, 2017
ISO 334.5 MB
English

e!COCKPIT

e!COCKPIT
V 1.4.0 (Größe: 2,1GB), Jan 24, 2018
ZIP

Runtime Software

Linux® Toolchain

Linux® Board Support Package (BSP) With the PFC BSP, WAGO offers Linux® enthusiasts the opportunity to compile the PFC firmware themselves, and to expand it according to their own wishes.

The WAGO PFC BSP includes a Pengutronix build environment, optimized for the PFC, and the OSELAS Toolchain, which open up the following possibilities, among others:

  • Expanding the firmware functions using open source packages like: Python, SQLite3, PHP, etc.
  • Compiling their own C/C++ applications with direct or indirect bus access to the local bus, CANopen, or PROFIBUS.
  • Compiling external libraries using CODESYS V2 to expand the PLC applications.
  • There are detailed instructions for many of these tasks and ideas (see How To's).
2018.2.1 (FW11), Feb 19, 2018
TXT 14.1 kB

Firmware

Firmware: 750-8202/025-001 Controller PFC200; 2 x ETHERNET, RS-232/-485; Telecontrol technology; Ext. Temperature
11, Jan 31, 2018
img 204.5 MB

IoT/ Cloud

Cloud Connectivity

Cloud Connectivity beta version
008, Oct 16, 2017
ZIP 8.0 MB

Compatible products

Carrier rail

General accessories

Marking accessories

shield connection

wiring and connectors

Your Shopping Cart

Added to shopping cart.
Go to the shopping cart Request offer. Continue shopping.

Are you sure?

Add project directly

Please enter an exact item number (e.g., 2002-1201) and confirm your entry with the “Enter” key. Use the “Tab” key to navigate between the columns.
PU (SPU)
Change Country

You are leaving the currently selected country website and will be logged out. Your user account only applies to one country. Your newly selected country website has other contacts and may have different content and functions.

Down
To top of page