Item no. 750-8213/040-010

Controller PFC200; 2nd Generation; 2 x ETHERNET M12, CAN, CANopen; Extreme; dark gray

Please wait ...
List price per piece*
On request
Price and availability after Login
Your price per piece*
On request
PU (SPU): 1 Piece
The value you entered was rounded.
Not available for order under SPU!
The item is already added and will not be added again. If necessary, please adjust the quantity directly on the article.
Invalid input
1
The PFC200 Controller is a compact PLC for the modular WAGO-I/O-SYSTEM. Besides network and fieldbus interfaces, this controller supports all digital and analog input/output modules, as well as specialty modules found within the 750/753 Series. Two ETHERNET interfaces and an integrated switch enable line topology wiring.
An integrated Webserver provides user configuration options, while displaying PFC200 status information.
In addition to the processing industry and building automation, typical applications for the PFC200 include standard machinery and equipment control (e.g., packaging, bottling and manufacturing systems, as well as textile, metal and wood processing machines).

Advantages:
  • Programming per IEC 61131-3
  • Programmable via WAGO-I/O-PRO V2.3 or e!COCKPIT
  • Direct connection of WAGO I/O Modules
  • 2 x ETHERNET (configurable), CAN, CANopen
  • Linux® operating system with RT‐Preempt patch
  • Configuration via CODESYS, e!COCKPIT or Web-Based Management user interface
  • Maintenance-free


The device is ideal for operation in harsh environments thanks to:
  • Extended temperature range
  • Greater immunity to impulse voltages and electromagnetic interference
  • Higher vibration and shock resistance

Product details

Details
Technical Data
Communication CANopen
Modbus (TCP, UDP)
Ethernet
ETHERNET protocols DHCP
DNS
NTP
FTP
FTPS
SNMP
HTTP
HTTPS
SSH
Visualization Web Visu
Operating system Real-time Linux (with RT-Preempt patch)
Programming languages per IEC 61131-3 Instruction List (IL)
Ladder Diagram (LD)
Function Block Diagram (FBD), Continuous Function Chart (CFC)
Structured Text (ST)
Sequential Function Chart (SFC)
Programming environment e!COCKPIT (based on CODESYS V3)
WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)
Configuration options e!COCKPIT
WAGO-I/O-CHECK
Web-based management
e!RUNTIME Library
CODESYS Library
Baud rate (communication/fieldbus 1) 10/100 Mbit/s
Baud rate ETHERNET: 10/100 Mbit/s
Transmission medium (communication/fieldbus) ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; M12 D-coded; 100 m maximum cable length
Main memory (RAM) 512 MB
Internal memory (flash) 4096 MB
Non-volatile hardware memory 128 Kbytes
Program memory CODESYS V2: 16 MB; e!RUNTIME: 32 MB
Data memory CODESYS V2: 64 MB; e!RUNTIME: 128 MB
Non-volatile software memory 128 Kbytes
Non-volatile software memory 128. Kbytes
Memory card type SD card
Memory card slot Push-push mechanism; Cover lid (sealable)
Number of modules per node (max.) 64
Input and output (internal) process image (max.) 1000 Worte/1000 Worte
Input and output (MODBUS) process image (max.) CODESYS V2: 1000 Worte/1000 Worte
Input and output (CAN) process image (max.) 2000 Worte/2000 Worte
Indicators LED (SYS, RUN, I/O, CAN, U1 … U6) red/green/orange: Status system, program, internal data bus, CANopen, status programmable by user (can be used via CODESYS library); LED (A, B) green: Status system power supply, field supply
Derating Derating (supply voltage): Surrounding air temperatures under laboratory conditions: (-25 … +30 %); for -40 … +55 °C: 24 V (-25 … +20 %); for +55 … +70 °C: 24 V (-25 … +10 %); Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)
Supply voltage (system) DC 24 V; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!
Input current (typ.) at nominal load (24 V) 550 mA
Total current (system supply) 1,700 mA
Supply voltage (field) DC 24 V; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed!
Current carrying capacity (power jumper contacts) 10 A
Number of outgoing power jumper contacts 2
Rated surge voltage 1 kV
Connection data
Connection technology: communication/fieldbus CANopen: 1 x D-sub 9 plug; Modbus TCP/UDP: 2 x M12 socket; 4-pole; D-coded
Connection technology: system supply 2 x CAGE CLAMP®
Connection technology: field supply 4 x CAGE CLAMP®
Connection type (1) System/field supply
Solid conductor 0.25 … 2.5 mm² / 24 … 14 AWG
Fine-stranded conductor 0.25 … 2.5 mm² / 24 … 14 AWG
Strip length 8 … 9 mm / 0.31 … 0.35 inch
Connection technology: device configuration 1 x Male connector; 4-pole
Physical data
Width 112 mm / 4.409 inch
Height 100 mm / 3.937 inch
Depth 71.9 mm / 2.831 inch
Depth from upper edge of DIN-rail 64.7 mm / 2.547 inch
Mechanical data
Weight 258.4 g
Color dark gray
Housing material Polycarbonate, polyamide 6.6
Conformity marking CE
Environmental Requirements
Surrounding air temperature (operation) -40 … 70 °C
Surrounding air temperature (storage) -40 … 85 °C
Protection type IP20
Pollution degree (5) 2 per IEC 61131-2
Operating altitude without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
Relative humidity (without condensation) 95 %
Relative humidity (with condensation) Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
Mounting position horizontal (standing/lying); vertical
Mounting type DIN-35 rail
Vibration resistance per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
Shock resistance per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
EMC immunity to interference per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26; EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
EMC emission of interference per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Commercial data
Packaging type BOX
Country of origin DE
GTIN 4055143920674
Customs tariff number 85371091990
Approvals / Certificates
Ex-Approvals
Approval
Additional Approval Text
Certificate name
Language
Approval: UL
Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS)
Additional Approval Text UL 121201
Certificate name: E198726 Sec.1
Ship Approvals
Approval
Additional Approval Text
Certificate name
Language
Approval: DNV GL
Det Norske Veritas, Germanischer Lloyd
Additional Approval Text -
Certificate name: TAA00000Y7
UL-Approvals
Approval
Additional Approval Text
Certificate name
Language
Approval: UL
Underwriters Laboratories Inc. (ORDINARY LOCATIONS)
Additional Approval Text UL 61010-2-201
Certificate name: E175199 Sec11
Downloads
Documentation
CAD files
CAD data
2D/3D Models 750-8213/040-010
CAE data
ZUKEN Portal 750-8213/040-010
Required accessories
Compatible products
Product family