Item no. 750-8216

Controller PFC200; 2nd Generation; 2 x ETHERNET, RS-232/-485, CAN, CANopen, PROFIBUS Slave; light gray

Stock item
Please wait ...
List price per piece*
On request
Price and availability after Login
Your price per piece*
On request
PU (SPU): 1 Piece
The value you entered was rounded.
Not available for order under SPU!
The item is already added and will not be added again. If necessary, please adjust the quantity directly on the article.
Invalid input
1

The PFC200 Controller is a compact PLC for the modular WAGO I/O System. Besides network and fieldbus interfaces, the controller supports all digital, analog and specialty modules found within the 750/753 Series.

Two ETHERNET interfaces and an integrated switch enable line topology wiring.

An integrated Webserver provides user configuration options, while displaying PFC200 status information.

Besides the processing industry and building automation, typical applications for the PFC200 include standard machinery and equipment control (e.g., packaging, bottling and manufacturing systems, as well as textile, metal and wood processing machines).

Programming per IEC 61131-3

  • Programmable via WAGO-I/O-PRO V2.3 or e!COCKPIT
  • Direct connection of WAGO I/O Modules
  • 2 x ETHERNET (configurable), RS-232/485, CAN, CANopen, PROFIBUS DP Slave
  • Linux operating system with RT‐Preempt patch
  • Configuration via CODESYS, e!COCKPIT or Web-Based Management interface
  • Maintenance-free

Product details

Details
Technical Data
Communication PROFIBUS
CANopen
Modbus (TCP, UDP)
Ethernet
Modbus RTU
RS-232 serial interface
RS-485 Serial Interface
EtherNet/IPTM Adapter (slave), library for e!RUNTIME
EtherCAT Master, requires an additional license
MQTT
ETHERNET protocols DHCP
DNS
NTP
FTP
FTPS
SNMP
HTTP
HTTPS
SSH
Visualization Web Visu
Operating system Real-time Linux (with RT-Preempt patch)
CPU Cortex A8; 1 GHz
Programming languages per IEC 61131-3 Instruction List (IL)
Ladder Diagram (LD)
Function Block Diagram (FBD), Continuous Function Chart (CFC)
Structured Text (ST)
Sequential Function Chart (SFC)
Programming environment e!COCKPIT (based on CODESYS V3)
WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)
Configuration options e!COCKPIT
WAGO-I/O-CHECK
Web-based management
e!RUNTIME Library
CODESYS Library
Baud rate (communication/fieldbus 1) 10/100 Mbit/s
Baud rate ETHERNET: 10/100 Mbit/s
Transmission medium (communication/fieldbus) ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
Main memory (RAM) 512 MB
Internal memory (flash) 4096 MB
Non-volatile hardware memory 128 Kbytes
Program memory CODESYS V2: 16 MB; e!RUNTIME: 32 MB
Data memory CODESYS V2: 64 MB; e!RUNTIME: 128 MB
Non-volatile software memory 128 Kbytes
Non-volatile software memory 128. Kbytes
Memory card type SD card
Memory card slot Push-push mechanism; Cover lid (sealable)
Number of modules per node (max.) 250
Number of modules without a bus extension (max.) 64
Input and output (internal) process image (max.) 1000 Worte/1000 Worte
Input and output (MODBUS) process image (max.) CODESYS V2: 1000 Worte/1000 Worte; e!RUNTIME: 16000 Worte/16000 Worte
Input and output (PROFIBUS )process image (max.) 244 Byte/244 Byte
Input and output (CAN) process image (max.) 2000 Worte/2000 Worte
Indicators LED (SYS, RUN, I/O, CAN, BF, DIA, U1 … U4) red/green/orange: Status system, program, internal data bus, CANopen, PROFIBUS, PROFIBUS diagnostics, status programmable by user (can be used via CODESYS library); LED (A, B) green: System power supply status, field supply
Supply voltage (system) DC 24 V(-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)
Input current (typ.) at nominal load (24 V) 550 mA
Total current (system supply) 1,700 mA
Supply voltage (actuator) ,
Supply voltage (field) DC 24 V (-25 … +30 %); via power jumper contacts
Current carrying capacity (power jumper contacts) 10 A
Number of outgoing power jumper contacts 3
Isolation 500 V system/field
Connection data
Connection technology: communication/fieldbus PROFIBUS: 1 x D-sub 9 socket; CANopen: 1 x D-sub 9 plug; Modbus TCP/UDP: 2 x RJ-45; Modbus RTU: 1 x D-sub 9 socket; RS-232 serial interface: 1 x D-sub 9 socket; RS-485 serial interface: 1 x D-sub 9 socket
Connection technology: system supply 2 x CAGE CLAMP®
Connection technology: field supply 6 x CAGE CLAMP®
Connection type (1) System/field supply
Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Strip length 8 … 9 mm / 0.31 … 0.35 inch
Connection technology: Device configuration 1 x Male connector; 4-pole
Physical data
Width 112 mm / 4.409 inch
Height 100 mm / 3.937 inch
Depth 71.9 mm / 2.831 inch
Depth from upper edge of DIN-rail 64.7 mm / 2.547 inch
Mechanical data
Weight 260.7 g
Color light gray
Housing material Polycarbonate, polyamide 6.6
Conformity marking CE
Environmental Requirements
Surrounding air temperature (operation) 0 … 55 °C
Surrounding air temperature (storage) -40 … 85 °C
Protection type IP20
Pollution degree (5) 2 per IEC 61131-2
Operating altitude without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
Relative humidity (without condensation) 95 %
Mounting position any
Mounting type DIN-35 rail
Vibration resistance 4g per IEC 60068-2-6
Shock resistance 15g per IEC 60068-2-27
EMC immunity to interference per EN 61000-6-2, marine applications
EMC emission of interference per EN 61000-6-3, marine applications
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H2S at a relative humidity < 75% 10 ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75% 25 ppm
Commercial data
Packaging type BOX
Country of origin DE
GTIN 4055143759809
Customs tariff number 85371091990
Approvals / Certificates
Ex-Approvals
Approval
Additional Approval Text
Certificate name
Language
Approval: ATEX
TUEV Nord Cert GmbH
Additional Approval Text EN 60079
Certificate name: TUEV_14_ATEX_148929_X
Approval: CCCEx
CQST/CNEx
Additional Approval Text CNCA-C23-01
Certificate name: 2020312310000213
Approval: IECEx
TUEV Nord Cert GmbH
Additional Approval Text IEC 60079-0
Certificate name: IECEx_TUN_14.0035_X
Approval: UL
Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS)
Additional Approval Text UL 121201
Certificate name: E198726 Sec.1
Country specific Approvals
Approval
Additional Approval Text
Certificate name
Language
Approval: KC
National Radio Research Agency
Additional Approval Text Article 58-2, Clause 3
Certificate name: MSIP-REM-W43-PFC750
Ship Approvals
Approval
Additional Approval Text
Certificate name
Language
Approval: ABS
American Bureau of Shipping
Additional Approval Text -
Certificate name: 19-HG1821926
Approval: DNV GL
Det Norske Veritas, Germanischer Lloyd
Additional Approval Text -
Certificate name: TAA0000194
Approval: LR
Lloyds Register
Additional Approval Text -
Certificate name: 02/20026 (E6)
Approval: PRS
Polski Rejestr Statków
Additional Approval Text -
Certificate name: TE/2236/880590/19
UL-Approvals
Approval
Additional Approval Text
Certificate name
Language
Approval: UL
Underwriters Laboratories Inc. (ORDINARY LOCATIONS)
Additional Approval Text UL 61010-2-201
Certificate name: E175199 Sec11
Downloads
Documentation
Bid Text
System Description
Application Notes
Application Note CoDeSys 2.3
Application Note e!COCKPIT
Libraries
Library
CAD files
CAD data
2D/3D Models 750-8216
CAE data
ZUKEN Portal 750-8216
Required accessories
Compatible products
Product family