Item no. 750-364/040-010

Fieldbus Coupler Modbus TCP M12; 4th generation; Extreme; dark gray

Please wait ...
List price per piece*
On request
Price and availability after Login
Your price per piece*
On request
PU (SPU): 1 Piece
The value you entered was rounded.
Not available for order under SPU!
The item is already added and will not be added again. If necessary, please adjust the quantity directly on the article.
Invalid input
1
The Modbus TCP/UDP Fieldbus Coupler connects ETHERNET to the modular WAGO-I/O-SYSTEM.
The fieldbus coupler detects all connected I/O modules and creates a local process image.
Two ETHERNET interfaces and an integrated switch allow the fieldbus to be wired in a line topology. This eliminates additional network devices, such as switches or hubs.
Both interfaces support autonegotiation and Auto-MDI(X).
The rotary switch configures the last byte of the IP address and may be used for IP address assignment (DHCP, BootP).

The coupler is designed for fieldbus communication in MODBUS® networks. It also supports a wide variety of standard ETHERNET protocols (HTTP(S), BootP, DHCP, DNS, SNMP, (S)FTP). An integrated Webserver provides user configuration options, while displaying coupler’s status information.

The device is ideal for operation in harsh environments thanks to:
  • Extended temperature range
  • Greater immunity to impulse voltages and electromagnetic interference
  • Higher vibration and shock resistance

Product details

Details
Technical data
Communication Modbus (TCP, UDP)
ETHERNET protocols HTTP(S)
BootP
DHCP
DNS
(S)FTP
SNMP
Baud rate 10/100 Mbit/s
Transmission medium Twisted Pair S-UTP; 100 Ω; Cat. 5; M12 D-coded; 100 m maximum cable length
Transmission performance Class D per EN 50173
Number of modules per node (max.) 64
Configuration options WAGO-I/O-CHECK
Web-based management
CODESYS Library
Input and output (fieldbus) process image (max.) 1020 Worte/1020 Worte
Supply voltage (system) DC 24 V; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!
Power consumption (5 V system supply) 350 mA
Total current (system supply) 1,700 mA
Supply voltage (field) DC 24 V; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed!
Input current (typ.) at nominal load (24 V) 500 mA
Power supply efficiency (typ.) at nominal load (24 V) 90 %
Rated surge voltage 1 kV
Indicators LED (LINK/ACT) green: Network connection via ports 1 … 2; LED (MS, NS) red/green: Status of node, network; LED (I/O) red/green/orange: Status of local data bus
Current carrying capacity (power jumper contacts) 10 A
Derating Derating (supply voltage): Surrounding air temperatures under laboratory conditions: (-25 … +30 %); for -40 … +55 °C: 24 V (-25 … +20 %); for +55 … +70 °C: 24 V (-25 … +10 %); Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)
Connection data
Connection technology: communication/fieldbus Modbus TCP/UDP: 2 x M12 socket; 4-pole; D-coded
Connection technology: field supply CAGE CLAMP®
Connection technology: system supply 2 x CAGE CLAMP®
Connection technology: device configuration 1 x Male connector; 4-pole
Connection type (1) System/field supply
Solid conductor 0.25 … 2.5 mm² / 24 … 14 AWG
Fine-stranded conductor 0.25 … 2.5 mm² / 24 … 14 AWG
Strip length 8 … 9 mm / 0.31 … 0.35 inch
Physical data
Width 112 mm / 4.409 inch
Height 100 mm / 3.937 inch
Depth 71.9 mm / 2.831 inch
Depth from upper edge of DIN-rail 64.7 mm / 2.547 inch
Mechanical data
Mounting type DIN-35 rail
Material data
Color dark gray
Housing material Polycarbonate, polyamide 6.6
Fire load 0.146 MJ
Weight 213.1 g
Conformity marking CE
Environmental requirements
Surrounding air temperature (operation) -40 … 70 °C
Surrounding air temperature (storage) -40 … 85 °C
Protection type IP20
Pollution degree (5) 2 per IEC 61131-2
Operating altitude without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
Mounting position horizontal (standing/lying); vertical
Relative humidity (without condensation) 95 %
Relative humidity (with condensation) Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
Vibration resistance per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
Shock resistance per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
EMC immunity to interference per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26; EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
EMC emission of interference per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H2S at a relative humidity < 75% 10 ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75% 25 ppm
Commercial data
Packaging type BOX
Country of origin DE
GTIN 4055143923026
Customs tariff number 85371091990
Approvals / Certificates
Ex-Approvals
Approval
Additional Approval Text
Certificate name
Language
Approval: UL
Underwriters Laboratories Inc. (HAZARDOUS LOCATIONS)
Additional Approval Text UL 121201
Certificate name: E198726 Sec.1
Ship Approvals
Approval
Additional Approval Text
Certificate name
Language
Approval: DNV GL
Det Norske Veritas, Germanischer Lloyd
Additional Approval Text -
Certificate name: TAA00000Y7
UL-Approvals
Approval
Additional Approval Text
Certificate name
Language
Approval: UL
Underwriters Laboratories Inc. (ORDINARY LOCATIONS)
Additional Approval Text UL 61010-2-201
Certificate name: E175199 Sec11
Downloads
Documentation
Compatible products
Product family
Couplers & I/O modules: XTR
I/O-System 750 XTR: Dort automatisieren, wo jedes andere System an seine Grenzen stößt – und das zuverlässig und wirtschaftlich! XTR – dieses Kürzel im Systemnamen steht für extremen Schutz vor klimatischen Einflüssen, Schwingungen, Erschütterungen und Überspannungen.