Shape
Item no. 750-889
Controller KNX IP
Item no. 750-889

Controller KNX IP

Item no. 750-889
Controller KNX IP

Description

This controller can accommodate up to two KNX logic devices at the same time.

  • 1. In conjunction with the WAGO-I/O-SYSTEM, the KNX IP Controller is used as a user-programmable application controller within KNX IP networks. The controller supports all digital, analog and specialty modules found within the 750/753 Series. The IEC 61131-3 programmable controller is capable of 10/100 Mbit/s data rates. KNX objects of any type (EIS/DPT) can be created using the programming tool. Libraries including pre-made function blocks are readily available on the WAGO Website for programming. The controller supports a maximum of 253 communication objects, as well as 254 group addresses and associations.
  • 2. Combined with the KNX/EIB/TP1 Module, the 750‐889 KNX IP Controller can operate as a router on an IP backbone (ETHERNET). No IEC application is required for router functionality.

Both devices are commissioned and configured via ETS software using the WAGO product database. The software includes a plug‐in that automatically installs and opens for configuration.

The KNX IP Controller features an integrated 2‐port 10/100 Mbit/s switch, allowing a line structure to be easily created without additional network components. The maximum number of controllers that can be wired in series is 20.

An internal server is available for Web-based applications.

The controller provides 1024 KB program memory, 1024 KB data memory and 32 KB retain memory. It is capable of multitasking, has a battery-backed, real-time clock and is based on a 32-bit CPU.

The controller offers many different application protocols for control tasks (MODBUS, KNXnet/IP) or for system management and diagnostics (HTTP, BootP, DHCP, DNS, AutoIP, SNTP, FTP, SNMP and SMTP).

The number of KNX/EIB/TP1 Modules (750‐646) supported by the KNX IP Controller does not depend on the application.


Note:

The WAGO ETS3/4 plug-in is a component of the WAGO-ETS3 product databank and can be downloaded for free at www.wago.com.

Product details

Details

Technical Data

Communication KNX IP
Modbus TCP
Ethernet
Ethernet protocol HTTP
BootP
DHCP
DNS
AutoIP
SNTP
FTP
SNMP V3
SMTP
Visualization Web-Visu
CPU 32 bits
Programming languages per IEC 61131-3 Instruction List (IL)
Ladder Diagram (LD)
Function Block Diagram (FBD), Continuous Function Chart (CFC)
Structured Text (ST)
Sequential Function Chart (SFC)
Programming environment WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)
Configuration options WAGO-I/O-CHECK
Web-based management
Max. length of network ≤ 2,000 m; max. 20 controllers in series
Baud rate (communication/fieldbus 1) 10/100 Mbit/s
Baud rate 10/100 Mbit/s
Fieldbus segment length max. 100 m
Transmission medium (communication/fieldbus) S-UTP; 100 Ω; Cat. 5
Program memory 1024 kByte
Data memory 1024 kByte
Software non-volatile memory 32 kbyte
Memory for fieldbus input variables max. 512 Byte
Memory for fieldbus output variables max. 512 Byte
Type of memory card SD and SDHC up to 32 GB (All guaranteed properties are only valid in connection with the WAGO 758-879/000-001 memory card.)
Memory card slot Push-push mechanism, sealable cover lid
Number of modules per node max. 250
Number of I/O modules without bus extension max. 64
Max. input and output process image (fieldbus) 2 kByte/2 kByte
Device-specific Number of group addresses: 254; Number of communication objects: 253
Indicators LED (LINK/ACT) green: Network connection port 1 … 2; LED (MS/PRG IP, NS/PRG RT) red/green: IP device programming mode, router; LED (I/O, USR) red/green/orange: Internal data bus status, status programmable by user; LED (A, B) green: System power supply status, field supply
System supply voltage DC 24 V (−25 … +30 %); via wiring level (CAGE CLAMP® connection)
Input current typ. at rated load (24 V) 500 mA
Efficiency of the power supply (typ.) at nominal load (24 V) 90 %
Current consumption, system supply 450 mA
Total current for system supply 1700 mA
Field supply voltage DC 24 V (-25 … 30 %); via power jumper contacts
Current carrying capacity of the power jumper contacts 10 A
Number of outgoing power jumper contacts 3
Isolation 500 V system/supply
KNX certified IP Controller: 61/8316/08; IP Router: 61/8317/08

Connection data

Connection technology: communication/fieldbus KNX IP: 2 x RJ-45; Modbus TCP/UDP: 2 x RJ-45
Connection technology: system supply 2 x CAGE CLAMP®
Connection technology: field supply 6 x CAGE CLAMP®
Connection type (1) System-/Feldversorgung
Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Strip length 8 … 9 mm / 0.31 … 0.35 Inch
Connection technology: device configuration 1 x 4-pole male connector

Geometrical Data

Width 61.5 mm / 2.421 Inch
Height 71.9 mm / 2.831 Inch
Height from upper-edge of DIN-35 rail 64.7 mm / 2.547 Inch
Depth 100 mm / 3.937 Inch

Mechanical data

Weight 192 g
Color light gray
Housing material Polycarbonate, polyamide 6.6
Conformity marking CE

Environmental Requirements

Ambient temperature (operation) 0 … 55 °C
Ambient temperature (storage) -25 … 85 °C
Degree of protection IP20
Degree of pollution (5) 2 per IEC 61131-2
Operating altitude without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); max.: 5000 m
Relative air humidity (no condensation) 95 %
Mounting position any
Type of mounting DIN-35 rail
Vibration resistance 4g per IEC 60068-2-6
Shock resistance 15g per IEC 60068-2-27
EMC immunity to interference acc. to EN 61000-6-2
EMC emission of interference acc. to EN 61000-6-3
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Fire load 2.658 MJ
Permissible H2S contaminant concentration at a relative humidity < 75 % 10 ppm
Permissible SO2 contaminant concentration at a relative humidity < 75 % 25 ppm

Commercial data

Packaging type BOX
Country of rigin DE
GTIN 4055143093330
Customs Tariff No. 85371091990

Approvals / Certificates

Ex-Approvals

Logo
Approval
Certificate name
Logo
Approval: UL
Underwriters Laboratories Inc.
(HAZARDOUS LOCATIONS)
Certificate name: E198726 Sec.1
English

Ship Approvals

Logo
Approval
Certificate name
Logo
Approval: DNV GL
Det Norske Veritas, Germanischer Lloyd
Certificate name: TAA00000Y7
English
Logo
Approval: DNV GL
Det Norske Veritas, Germanischer Lloyd
Certificate name: TAA00000Y7 Rev.1
English
Logo
Approval: DNV GL
Det Norske Veritas, Germanischer Lloyd
Certificate name: TAA0000194
English

UL-Approvals

Logo
Approval
Certificate name
Logo
Approval: UL
UL International Netherlands B.V.
(ORDINARY LOCATIONS)
Certificate name: E175199 Sec.1
English

Downloads

Documentation

Manual

KNX IP Controller 32-bit CPU with Multitasking
Oct 4, 2016
PDF 16.5 MB
Use in Hazardous Environments Term definition, marking and installation regulations
May 8, 2014
PDF 1.0 MB
Design Notes Basic conditions and recommendations for higher operational safety
May 3, 2011
PDF 1.5 MB

Bid Text

750-889 IO, Controller
Jan 22, 2016
DOC 35.3 kB
German

System Description

750 Controller, General Product Information
Jun 6, 2017
PDF 426.1 kB
Overview on WAGO-I/O-SYSTEM 750 approvals
Jun 6, 2017
PDF 314.9 kB

Application Notes

Application Note CoDeSys 2.3

WAGO product data base for the 750-889 / 750-849 KNX IP Controller including plug-in for ETS
2.0.318.457, Sep 16, 2016
VD4 1.1 MB
WAGO_Datalogger_02.lib The FbDatalogger function block logs entries from up to 80 channels at an interval of min. one second in a CSV file.
Nov 13, 2017
ZIP 678.0 kB
Application Note flexROOM® Weather Decoder This Application Note explains how the flexROOM® Weather application can be integrated into a project in which no flexROOM® Office distribution boxes are used.
Aug 7, 2015
ZIP 1.1 MB
German
KNX Function Macros Based on the KNX_02.lib library, WAGO provides various function macros in the field of building automation.
Feb 2, 2017
ZIP 110.0 MB
Application Note PowerMeasurement_03 Library This application note describes how current, voltage, effective power, power factor and energy consumption can be measured using 3-phase power measurement modules (750-493).
Mar 19, 2014
ZIP 954.5 kB
Application Note DaylightSaving This Application Note explains how automatic switching between standard/daylight savings time can be implemented on the Ethernet fieldbus controller 750-841, starting from Firmware version 11.
Mar 19, 2014
ZIP 682.4 kB
HVAC System Macros WAGO provides system macros for HVAC applications that are based on Building_HVAC_03.lib.
Jun 14, 2017
ZIP 13.4 MB
Application Note: DMX_02 This application note describes how a DMX master for DMX device control can be performed via 750-652 serial interface.
Apr 26, 2017
ZIP 751.0 kB
Connection of a Thermokon Thanos SR L MODBUS room control unit to the WAGO-I/O-SYSTEM The fundamental method of setting up communication between the WAGO I/O System and the Thanos SR L MODBUS room operating panel from Thermokon is described in this application note.
Mar 19, 2014
ZIP 313.2 kB
Application Note: MpBus_03 Library This Application Note explains how a WAGO fieldbus controller sets up communication to the MP-bus actuators via the MP-bus master module (750-643).
Apr 13, 2018
ZIP 1.4 MB
Application Note Connecting with an iPod Touch This Application Note explains the basic procedures for access to the WAGO Ethernet Controller 750-8xx or the WAGO Ethernet Coupler 750-3xx using an iPod Touch.
Mar 19, 2014
ZIP 440.7 kB
German
Application Note Scheduler_03.lib This application note describes different applications of the Scheduler_03.lib library.
Mar 5, 2014
ZIP 1.8 MB
Connection of the WS-K xx T ModBus HVAC Electronic Weather Forecast Station The Application Note explains how communication between the WAGO-I/O-SYSTEM and an HKW electronic weather forecast station (compact) can be established.
V 1.1, Jul 7, 2017
ZIP 781.1 kB
GRUNDFOS GENIbus interface, application note This application note describes how communication between the WAGO-I/O-SYSTEM and the Grundfos MAGNA series circulation pumps can be performed via GENIbus interface.
Mar 20, 2017
ZIP 286.6 kB
Connection of Thermokon Multi-function room control units WRF 06 The fundamental method of setting up communication between the WAGO I/O System and the multi-function room operating panel (WRF06 RS485 Modbus) from Thermokon is described in this application note.
Apr 8, 2016
ZIP 413.6 kB
Connection of DMX devices to the WAGO-I/O-SYSTEM via the ArtNet-DMX STAGE-PROFI 1.1 This application note describes connecting the ArtNet-DMX STAGE-PROFI 1.1 to the WAGO-I/O-SYSTEM. The ArtNet-DMX STAGE-PROFI 1.1 can be operated as a DMX master and a DMX slave.
Mar 19, 2014
ZIP 1.5 MB
KNX Macro Switching Actuator This macro demonstrates how the WAGO-I/O-SYSTEM can be used as a KNX switching actuator.
Sep 23, 2015
ZIP 9.7 MB
English
Application Note for the 750-494 3-Phase Power Measurement Module The application note for the 3-Phase Power Measurement Module 750-494 shows how the measured values ​​of the power measurement module can be read. It is also shown how the power module can be configured using the WAGO-I/O-PRO- V2.3 visualization tool.
Nov 11, 2014
ZIP 1.7 MB
Connection of Thermokon Multi-function room control units WRF 08 The fundamental way of carrying out the communication between the WAGO I/O System and the multi-function room operating panel (WRF08 RS485 Modbus) from Thermokon is described in this application note.
Mar 19, 2014
ZIP 931.8 kB
Application Note KNX StarterKit3 This Application Note includes the commissioning instructions for the KNX IP StarterKit 3.
Sep 28, 2017
ZIP 30.9 MB
Application Note for the 750-495 3-Phase Power Measurement Module The application note for the 3-Phase Power Measurement Module 750-495 shows how the measured values ​​of the power measurement module can be read. It is also shown how the power module can be configured using the WAGO-I/O-PRO- V2.3 visualization tool.
Mar 20, 2014
ZIP 1.8 MB
Application Note Weather Station Elsner P03 Modbus This application note describes how communication can be set up between the WAGO I/O System and the ELSNER P03/3 weather station with a Modbus interface.
Mar 18, 2014
ZIP 275.6 kB
Application Note: EnOcean_06 Library This application note describes how communication between the WAGO-I/O-SYSTEM and different EnOcean wireless sensors can be implemented using the EnOcean_06.lib library.
Nov 30, 2016
ZIP 842.0 kB
Application note: DALI 753-647 Configuration Interface This application note describes the WAGO DALI Configurator, the integration of the DALI visualization for configuring various sensor types and the implementation in a program.
Jun 20, 2017
ZIP 2.9 MB
HVAC System Macros for TRIC In this file you will find both templates and macros for the TRIC planning software. TRIC is a tool for planners and manufacturers of HVAC systems, which complies with the VOB [Construction Tendering and Contract Regulations], VDI [Association of German Engineers], and DIN EN ISO guidelines.
Jul 24, 2015
ZIP 76.8 MB
German
Application Note Library ModuleAccess_01 These instructions describe the use of the ModuleAccess_01.lib library using 4 examples.
Jan 29, 2016
ZIP 1.0 MB

Libraries

Library

ModuleAccess_01.lib The ModuleAccess_01 library provides both module configuration and access to its process data within a CoDeSys project without the use of WAGO I/O Check.
Feb 16, 2018
ZIP 1.5 MB
WAGO_Datalogger_02.lib The FbDatalogger function block logs entries from up to 80 channels at an interval of min. one second in a CSV file.
Nov 13, 2017
ZIP 678.0 kB

Product database

WAGO product data base for the 750-889 / 750-849 KNX IP Controller including plug-in for ETS
2.0.318.457, Sep 16, 2016
VD4 1.1 MB
WAGO product data base for 750-889 / 750-849 + 753-646 KNX Routers
2.0.373.598, Sep 16, 2016
KNXPROD 42.1 kB

Engineering-Software

Configuration and Commissioning Software

WAGO-IO-PRO Demo Version / 750, 758 and 762 Series
2.3.9.53, Jun 20, 2017
ISO 334.5 MB
English

Runtime Software

Firmware

Firmware: 750-889 Controller KNX IP
10, Nov 16, 2016
zip 1.7 MB

smartDATA

CAD data

3D Download 750-889
URL

Compatible products

Carrier rail

General accessories

Marking accessories

shield connection

wiring and connectors

Your Shopping Cart

Added to shopping cart.
Go to the shopping cart Request offer. Continue shopping.

Are you sure?

Add project directly

Please enter an exact item number (e.g., 2002-1201) and confirm your entry with the “Enter” key. Use the “Tab” key to navigate between the columns.
PU (SPU)
Change Country

You are leaving the currently selected country website and will be logged out. Your user account only applies to one country. Your newly selected country website has other contacts and may have different content and functions.

Down
To top of page